Skip to content

HP 서버 disk 증설 (hpacucli 사용)

조회 수 5132 추천 수 0 2015.08.05 12:27:26

# hpacucli ctrl slot=0 pd all show


Smart Array P410i in Slot 0 (Embedded)


   array A


      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)

      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)


   array B


      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK)

      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)

      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK)

      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)


현재 두개의 Logical볼륨이 생성 되어있음


서버에 disk 를 꽂은 후에 다시 정보 확인 ( 146G 디스크 2개 꽂음 )


# hpacucli ctrl slot=0 pd all show


Smart Array P410i in Slot 0 (Embedded)


   array A


      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)

      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)


   array B


      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK)

      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)

      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK)

      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)


   unassigned


      physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 146 GB, OK)

      physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 146 GB, OK)


# hpacucli ctrl slot=0 create type=ld drives=2I:1:7,2I:1:8 raid=1


위 커맨드로 디스크 두개를 raid 1 로 구성 [컨트롤러 슬롯번호 / 디스크 베이 번호 를 확인하여 맞춰줄것]


구성 후 다시 정보 확인


# hpacucli ctrl slot=0 pd all show


Smart Array P410i in Slot 0 (Embedded)


   array A


      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)

      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)


   array B


      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK)

      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)

      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK)

      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK)


   array C


      physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 146 GB, OK)

      physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 146 GB, OK)


구성 된 것 확인 후 fdisk 를 사용 하여 포멧 및 파일시스템 설정 후 마운트 

profile

일요일은 짜빠게뤼~ 먹는날~^^

엮인글 :
http://adminplay.com/417561/782/trackback
List of Articles
번호 제목 글쓴이 날짜 조회 수sort

도메인 Status 상태별 설명 안내

dpkg 사용법

HDD Guardian (a graphical user interface for smartctl)

ubuntu 10.04 에서 Nginx, Mysql, PHP5

HP 서버 disk 증설 (hpacucli 사용)

top 화면 내용중 load average와 PRI : priority(우선순위...

리눅스 메모리 관리, 왜 메모리 여유공간이 없을까? (top ...

make 정리

ZFS 파일에 ACL 설정

windows smartctl

EXT4 파일 시스템을 Btrfs 파일 시스템으로 변환하기

SSL 패스워드 삭제 하기

tar 압축을 실수로 디렉토리 생성 안하고 풀었을때 대처법

ll 명령시 날짜 전체가 보이도록 하기

hddtemp와 mrtg를 이용한 하드디스크 온도 체크 file

python과 mysql 연동시 libmysqlclient_r.so.* 에러가 날 ...

error: Hm, kex protocol error: type 30 seq 1 [preauth]... file

linux 커널 파라메터 수정

우분투(Ubuntu) ssh 설정하기

운영중인 Linux 서버에서 NTFS 파일 시스템 삭제하기

Copyright ADMINPLAY corp. All rights reserved.

abcXYZ, 세종대왕,1234

abcXYZ, 세종대왕,1234