# hpacucli ctrl slot=0 pd all show Smart Array P410i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) array B physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) |
현재 두개의 Logical볼륨이 생성 되어있음
서버에 disk 를 꽂은 후에 다시 정보 확인 ( 146G 디스크 2개 꽂음 )
# hpacucli ctrl slot=0 pd all show Smart Array P410i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) array B physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) unassigned physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 146 GB, OK) physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 146 GB, OK) |
# hpacucli ctrl slot=0 create type=ld drives=2I:1:7,2I:1:8 raid=1
위 커맨드로 디스크 두개를 raid 1 로 구성 [컨트롤러 슬롯번호 / 디스크 베이 번호 를 확인하여 맞춰줄것]
구성 후 다시 정보 확인
# hpacucli ctrl slot=0 pd all show Smart Array P410i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) array B physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) array C physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 146 GB, OK) physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 146 GB, OK) |
구성 된 것 확인 후 fdisk 를 사용 하여 포멧 및 파일시스템 설정 후 마운트